<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-05 11-49-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
102.20 MHz 4/5, 75 dBuV YLE X3M
Pilot RDS Phase Difference
6.6 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 51 kHz 8989 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,5 dBr 1,98 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLE X3M " 6204 10 (Pop M) 1 0 1 1 11:49, 5.11.2026
RT
"MANGE SCHMIDT - Glassigt "
AF EON
95.2, 97.3, 98.2, 98.6, 98.9, 99.4, 99.7, 100.0 MHz 6207, 6201, 6202, 6203
FM Scope Max at: 51 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2026.11.05 11.48.09 Total samples: 8989 Equivalent time: 0:07:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 3,7 dBr MIN: -0,5 dBr AVE: 1,98 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2026.11.05 11.48.09) 11.34 11.36 11.38 11.40 11.42 11.44 11.46 11.48 -1 0 1 2 3 4 Pm [dBr]